WARNING: This stage requires a qualified electrician and conformance with both the National
Electrical Code and local building codes. Turn off the power to the circuit connected to the light
fixture at the disconnect means. Failure to do so could result in death or serious injury.
MEASURE FOR CLEARMIRROR INSTALLATION
With mirror removed, mark junction box location on the wall where the sink's center meets the
top edge of the ClearMirror heater. Normally 2 inches higher than the tallest user as shown in
Figure 1.
INSTALL ELECTRICAL BOX
Shut off power to the circuit where heater is to be connected at the disconnect means.
• Use a keyhole saw or drywall router to cut a tight fit for the remodelers' box.
• Install remodeler's electrical junction box and tighten screws until junction box is secure in
the opening.
WIRE TO OVERHEAD LIGHT FIXTURE
• Disconnect overhead light fixture base from the wall to expose the junction box.
• Drop down a Romex (non-sheathed) cable to the ClearMirror junction box below.
APPLY CLEARMIRROR TO MIRROR BACK
• Before attaching ClearMirror pad onto mirror, re-measure the
sink's center and height position and mark an 'X' on the back
of the mirror at this location (see Figure 1).
• Clean area of mirror application with isopropyl alcohol
solution to remove residues and dry excess moisture
WARNING: Do not use any fuel-based cleaners.
• Apply ClearMirror to mirror by removing contact paper
and aligning edge of leads connection over the 'X' on the
back of the mirror.
• Press firmly around all edges and through the
middle of the ClearMirror heater pad.