dixell XR06CX Handmatig - Pagina 2
Blader online of download pdf Handmatig voor {categorie_naam} dixell XR06CX. dixell XR06CX 2 pagina's. Digital controller with defrost and fans management
Ook voor dixell XR06CX: Bedieningshandleiding (3 pagina's)
Temperature Setting Codes
We recommend a differential of 5-6 degrees, -4/-5 as a low temperature and 1 as a high temperature.
To change this, you will need to change BOTH the differential and the temperature settings.
Parameter Code
Defrost Settings
Defrosting is pre-set to occur at regular 4 to 6-hour intervals for 25 minutes. There is a 2-minute delay
after defrosting to allow the water to drip into the evaporation tray before the compressor and fan will
start again. To manually start a defrost cycle, press the "defrost" button for 3 seconds. This will also
cancel a defrost in progress. To change the defrost settings, follow the steps to enter the parameters as
shown above.
Parameter Code
833-734-8880
Iron Mountain Refrigeration & Equipment, LLC
Setting
Hy
Temperature differential
LS
Low Temperature
US
High Temperature
Setting
id
Defrost Interval
Nd
Maximum Defrost Time
dt
Drip Delay after Defrost
Fd
Fan Delay after Defrost
DF
Defrost Display
Dixell XR06CX Temperature Control Manual
Recommended
6
- 5
1
Pre-Set
4 hours
25 min
2 min
10 min
Def