Alto-Shaam Halo HeatI TM2-48/DLX Installatie, bediening en onderhoud - Pagina 7
Blader online of download pdf Installatie, bediening en onderhoud voor {categorie_naam} Alto-Shaam Halo HeatI TM2-48/DLX. Alto-Shaam Halo HeatI TM2-48/DLX 19 pagina's. Island takeout merchandiser
E L E C T R I C A L C O N N E C T I O N
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
D
N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the "
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
E L E C T R I C A L - I T M 2 - 4 8
/
VOLTAGE
PHASE
CYCLE
120
1
60
E L E C T R I C A L - I T M 2 - 7 2
/
VOLTAGE
PHASE
CYCLE
120
1
60
" position.
OFF
kW
HZ
AMPS
CORD
11.0
1.32
15A - 125V Plug
kW
HZ
AMPS
CORD
16.0
1.90
20A - 125V Plug
#880 • INSTALLATION/OPERATION/SERVICE MANUAL • 6.
REGARDING INTERNATIONAL
STANDARD UNITS:
If the unit is not equipped with flexible cord
with plug, an all-pole country approved
disconnection device which has a contact
separation of at least 3mm in all poles must be
incorporated in the fixed wiring for disconnection.
When using a cord without a plug, the
green/yellow conductor shall be connected to the
terminal which is marked with the ground symbol.
If a plug is used, the socket outlet must be easily
accessible. If the power cord needs replacement,
use a similar one obtained from the distributor.
For 230V units: To prevent an electrical shock
hazard between the appliance and other
&
PLUG
appliances or metal parts in close vicinity, an
NEMA 5-15P
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts to
provide sufficient protection against potential
&
PLUG
NEMA 5-20P
difference. The terminal is marked with the
following symbol.
I N S T A L L A T I O N
D
N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
D
N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.