ABC PROIZVOD Concept 2 mini air Technische instructies - Pagina 11
Blader online of download pdf Technische instructies voor {categorie_naam} ABC PROIZVOD Concept 2 mini air. ABC PROIZVOD Concept 2 mini air 16 pagina's. Central heating cookers
IIMPORTANT NOTE:
First fuel feeding may cause condensation – water drops and humidity in the ashtray. In
this case, increase the cooker temperature gradually and this phenomenon will disappear.
6.2. OPERATION
The cooker is fed with fuel as all the other continuously burning solid fuel boilers. The fire is
started with the ashtray door open. Having opened the firebox door, put the paper and small
prices of wood on the grid and start the fire. Put the heating material gradually into the firebox until
the fire intensifies. Only then fill the firebox, close the ashtray door and set the drought controller
to the desired temperature.
6.3. USE OF GRID
The cooker has water-cooled grid, made of seamless tubes as well as ash ejector, F.1 and F.2,
pos. 7, allowing efficient ash ejection from firebox into the ashtray. This enables a better fresh air
supply to combustion area. The cooker also has a feature that the firebox may be lifted with the
grid, which is placed on suitable holders.
The grid is an accessory, and if desired, the customer may either purchase it directly from the
manufacturer or order it through a distributor. This grid is intended for use in a transitional season,
when external temperature is not too low. Placing this grid, the heating effect on the hob is
enhanced, and thus food is boiled and roasted faster, and the cooker may also be used for
heating confined premises.
6.4. TEMPERATURE CONTROL
On the cooker panel, F.1 and F.2, pos. 8, a drought controller is installed, which function is to set
the desired temperature, and in consists of a numerical wheel with 0-8 scale, then of controller
flap and capillaries. A thermometer is installed on the cooker, F.1 and F.2 pos. 2, showing the
water temperature in the cooker. By means of capillaries, the draught controller (as well as the
thermometer) is connected with the probe from which it collects the details about water
temperature value in the cooker.
The cooker temperature is the lowest when the drought controller is set to no.1, and it is the
highest when the drought controller is set to no 8. When the cooker temperature starts to fall, the
controller flap is open automatically by 3-5 mm, allowing the flow of secondary drought (air) and
better combustion up to the desired temperature. the drought controller settings depend on the
desired area temperature.
IMPORTANT NOTE:
For correct functionality of the drought controller, connect the cooker to the chimney with
stipulated dimensions.
10