END PANEL INSTALLATION

The steps that follow describe one way to complete the
end panel installation. The materials and parts needed to
assemble the end panels include:
Corrugated polycarbonate panels: check diagrams for
size and panel positions.
Tek screws (#FA4482B) and neo-bonded washers
(#102921B)
Read the following information before starting:
Tek screws and neo-bonded washers are used to
secure panels to end frame.
During preparation, rest the edges of the panels on
cardboard or other material to protect them from dirt
and damage.
Consult the polycarbonate panels (Quick Start
section) for the location and lengths of each panel.
The diagrams are located at the back of these
instructions.
Diagrams throughout this procedure show installing
the panels flush with the outer edge of the ground
posts or rafter legs. If sidewall panels are present,
adjust the panel position as needed to connect with
the sidewall panel to create a finished corner.
ATTENTION: Panels must be positioned as shown on the
panel diagrams. Using a panel in the incorrect place can
affect the placement of subsequent panels.
Install all accessories (fans, vents, heaters, etc.) after
installing all polycarbonate sheets.
If a door accessory was purchased, install the
door before attaching the end panels. Adjust the
panel position as needed to accommodate the door
installation. Consult the door installation manual (if
present) for additional details.
Complete the following steps to install the end panels.
Consult the polycarbonate panels diagrams located in the
Quick Start section, select one panel, begin at the edge of
the end frame, and work toward the opposite edge of the
end frame.
NOTE: Set end panels in a position that prepares for the
installation of the sidewall panels if equipped. This may
include shifting the outside panels beyond the end rafter
leg/ground post so corner panels align with each other.
Install all UV-protected surfaces to the outside toward the
sun. See information printed on the panel.
Revision date: 06.04.10
End Panel Installation
1.
Set the first lower 50" x 12' 2" panel in place as shown
with the edge aligned with the outside edge of the end
rafter and the bottom edge flush against the ground.
Do not attach at this time.
Brace panel in correct position and
mark a line on the panel along the
Trace and
remove
end cap attached to the top of the end
excess
rafter. Remove panel and cut to fit.
panel.
Shift panels as needed to create a
finished corner joint where end panels
meet sidewall panels (if equipped).
See Quick Start section for example.
50" x 12' 2"
Actual end frame may differ from frame shown; end panel
installation is the same. Consult the panel diagrams located
in the Quick Start section for your end panel kit.
2.
Trace along the end cap on the end rafter to mark the
panel.
End cap
attached to
top of end
rafter.
3.
Remove panel, cut along trace line, and set panel
back into position by tucking the top edge under the
end cap. Do not damage any panel section cut from a
main panel; these may be used in another position.
4.
Verify that the panel is flush with the ground and in the
desired position. See the Quick Start diagrams to view
frames with sidewall panels. Attach panel to the end
frame.
35' Wide Frame
is shown.
Panel
GROUND LEVEL
END CAP
Position top of panels
between rafter and lip of
the end cap.
GROUN
5