ClearSpan R030A00007 Handmatig - Pagina 7

Blader online of download pdf Handmatig voor {categorie_naam} ClearSpan R030A00007. ClearSpan R030A00007 11 pagina's. Corrugated polycarbonate end panel kit 30' wide & 35' wide

END PANEL INSTALLATION (continued)
9.
With the bottom row of panels installed, measure from
the top of the end rafter to the bottom of the top girt.
10.
Use this measurement to cut the first section of a
50" x 12' 2" panel. Typical overlap is 6".
11.
Holding the pre-cut panel in place, trace along the end
rafter to mark where the panel needs to be cut to fit
under the end cap.
12.
Remove panel, cut along traced line, and set panel
back into position by tucking the top edge under the
end cap. The top panel overlaps the lower panel.
13.
Verify the bottom edge of the panel aligns with the top
girt and attach the top panel to the end frame using
Tek screws and washers.
14.
Continue measuring, cutting and installing the
remaining sections of the 50" x 12' 2" panel until the
top row is complete.
15.
Continue by reading the care and maintenance
section that follows.
Measure from the top
of the end rafter to the
bottom of the top girt.
Revision date: 04.13.09
End Panel Installation
Trim excess panel
Secure panel by installing Tek screws through both the
top and bottom panels and into the girt.
x
Ground Level
Tek screws
and washers
Sample End Wall Complete
7