Dixon Bayco 3020 Series Installatie- en bedieningsinstructies - Pagina 4

Blader online of download pdf Installatie- en bedieningsinstructies voor {categorie_naam} Dixon Bayco 3020 Series. Dixon Bayco 3020 Series 4 pagina's. 2 inch swing check valves

2" Swing Check Valves
How to Inspect
1. Our easy opening access door allows for quick viewing of the
valve to ensure there is no blockage in the system.
2. Remove the inspection cap/cover and hand operate valve to
ensure springs are in good working order and flapper seats properly
without restriction.
3. Inspect springs and shaft for wear or broken springs.
4. Inspect valve seat for wear or gaps.
5. Inspect for product stuck in flapper assembly or valve seat causing
the flapper to hang open.
6. During re-assembly when closing access cap ensure O-ring is
properly seated and locking ring is fully engaged when closed, and
install cap.
Should problems be encountered replace valve immediately.
Inspection Frequency
Swing check valves should be routinely inspected as part of a
preventative maintenance schedule for dry bulk tankers. The units
should be given, at a minimum, a visual/manual inspection every 2-3
months.
Dixon Bayco Warranty
For complete warranty information, please refer to the latest
Dixon catalog.
4
877.582.3569
2" SCV