3. Remove the top cap. This will give you a clear view into the top of the air purifier. The photo on the right
shows the UV chamber with the UV lamp inserted in its center. Note that the UV chamber has a half-
round notch in its wall and that the lamp end cap has a groove in its top. The notch and the groove will
be in alignment.
4. Wear a pair of leather gloves. While holding down the air purifier on the counter with one hand, grasp
the lamp end cap with the other hand, and pull the UV lamp straight out. Note that it does not require
much force to "un-click" the UV lamp from its socket. Do not jerk it out. The UV lamp is fragile; excessive
force or dropping it may cause it to break. Should the lamp break while it is still in its chamber, do not
proceed further. Package the entire unit securely and ship it back to ClearWaveAir Corporation (see
ClearWaveAir.com for the address and shipping instructions). The unit will have to be cleaned of all
debris and contaminants before it is reassembled and returned to you.
10 • ClearWaveAir