Altronix 220VAC Series Installatiehandleiding - Pagina 2
Blader online of download pdf Installatiehandleiding voor {categorie_naam} Altronix 220VAC Series. Altronix 220VAC Series 8 pagina's. Cctv power supplies
Altronix Isolated CCTV Power Supplies provide 24VAC distributed via eight (8) or sixteen (16) fuse or PTC protected
isolated outputs for powering CCTV cameras, heaters, and other video accessories.
Altronix
Model Number
ALTV248Hi220
ALTV248CBHi220
ALTV248Mi220
ALTV248CBMi220
ALTV2416i220
ALTV2416CBi220
Input:
• 220VAC, 50/60Hz.
Output:
• Eight (8) or sixteen (16) fuse or PTC
protected outputs.
• 24VAC outputs.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Surge suppression.
Features:
• Individual electronically isolated outputs.
• Illuminated master Power ON/OFF switch
with built-in circuit breaker.
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all
Illuminated Power Disconnect
Circuit Breaker with manual reset
local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place
the enclosure's upper keyholes over the two upper screws, level and secure. Mark the position of the lower
two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's
upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pgs. 7, 8). Secure enclosure to earth ground.
4A
2. Set power switch to OFF position on all models (Fig. 1 - 3, pgs. 4 - 6).
250V
3. All units are factory set for 24VAC operation.
4. Connect unswitched AC circuit (220VAC, 50/60Hz) as follows: Green branch wire (ground) connects to the
terminal marked
[N] of the Inlet Appliance Connector. (Fig. 1 - 3, pgs. 4 - 6).
Use 18 AWG or larger for all power connections (Battery, AC output).
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1A - 8A] and [1B - 8B] are of the same polarity (phase).
6. Connect CCTV cameras to output terminals using the following procedure:
Camera 1 to output 1A & 1B.
Camera 2 to output 2A & 2B.
Camera 3 to output 3A & 3B.
Camera 4 to output 4A & 4B.
7. Set power switch on all models to the "RESET" (ON) position (Fig. 1 - 3, pgs. 4 - 6).
8. Upon completion of the wiring, secure enclosure door with screws (supplied).
- 2 -
Isolated Power Supply Reference Chart:
Total
Output
Output
Voltage
Current
24VAC
14A
24VAC
24VAC
12.5A
24VAC
24VAC
28A
24VAC
Installation Instructions:
Input
, Line connects to the terminal marked [L], and Neutral connects to the terminal marked
220VAC, 50/60Hz
Overview:
Number
PTC Protected
of
auto-resettable
Outputs
Outputs
8
8
8
8
16
16
Specifications:
Features (cont'd):
• Unit maintains camera synchronization.
• Ease of installation saves time & eliminates
costly labor.
• Spare fuses included (on fuse protected models).
Enclosure Dimensions (H x W x D approx.):
ALTV248Mi220, ALTV248UCBMi220:
8.5" x 7.5" x 3.875" (215.9mm x 191mm x 98.4mm).
ALTV248Hi220, ALTV248CBHi220,
ALTV2416i220, and ALTV2416CBi220:
13.5" x 13" x 3.25"
(342.9mm x 330.2mm x 82.6mm).
Fuse
Protected
Outputs
–
P
–
P
–
P
–
P
–
P
–
P
Camera 5 to output 5A & 5B.
Camera 6 to output 6A & 6B.
Camera 7 to output 7A & 7B.
Camera 8 to output 8A & 8B.
Isolated 220 Series Installation Guide
Output
220VAC
Current
50/60Hz
(max per
Input
output)
Current
1.75A
2.7A
1.6A
1.75A
5.4A