AHnet PROTOCOL
AHnet protocol
Uses 5 bytes communication:
BYTE 0
BYTE 1
BYTE 2
BYTE 3
BYTE 4
Commands
COMMAND
FA XX 01 01 00
FA XX 01 00 00
FA XX 04 01 00
FA XX 04 00 00
FA XX 14 00 00
XX
Number of the unit address. Up to 30 units for each RS422 BUS
CB1
Response in 8 bites of the unit status
CB2
Response in 8 bites of the unit status
12
START BYTE
ADDRESS BYTE
COMMAND BYTE
VALUE 1
VALUE 2
DESCRIPTION
GO UP
GO DOWN
BUTTON LOCK
BUTTON UNLOCK
INQUIRY CONTROL BYTE
RESPONSE
FB XX 01 01 00
FB XX 01 00 00
FB XX 04 01 00
FB XX 04 00 00
FB XX 14 CB1 CB2