FITKIT FT100S Gebruikershandleiding - Pagina 10
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} FITKIT FT100S. FITKIT FT100S 13 pagina's.

.
Translation of Error Codes
Fault
Failure Description
code
Communication
E1
when the power is on, the
connection
controller and the console is
abnormal.
E2
No signal from motor.
Over current protection:
In
E5
controller detects the current to
be over 6A for more than 3
seconds.
Explosion-proof impact
E6
protection: the abnormal
voltage or motor cause the
faulty of circuit that drive the
motor.
E7
Without putting the safety Key
Abnormal:
between
lower
working,
the
lower
Possible Cause: the communication between the lower controller
and console is blocked, check each joint between the controller
and console, ensure that each core is fully plugged in. Check the
connection line, replace it if it's damaged.
Possible Cause:
Check the motor cable to see whether it is connected well or not, if
not, connect the motor wire again.
Check the motor cable to see whether it is damaged or has a burnt
smell, if yes, replace the motor.
Check the speed sensor to see whether it is correctly installed or
damaged
Possible Cause:
Overloading leads to excessive current, and the system stop out of
self-protection, or some part is stuck, causing the motor to stop.
Adjust the treadmill and restart it. Check if there is liquid or burnt
smell while the motor is running, if yes, replace the motor; check
if the controller has a burned smell, if yes, replace the controller;
check the power supply voltage, if it does not match the
specifications, change into correct voltage and test the machine
again.
Possible Cause:
Check if the power supply voltage is 50% lower than normal
voltage ,use the correct voltage and test the machine again;
check if the controller has a burnt smell and replace the controller;
Check if the motor cable is connected and connect the motor wire
again.
Put the safety key on the right place.
8
Fault Handling