EdilKamin IRIS Handmatig - Pagina 3
Blader online of download pdf Handmatig voor {categorie_naam} EdilKamin IRIS. EdilKamin IRIS 12 pagina's.
HEATING SPECIFICATIONS
Hopper capacity
Ef!ciency
Available power
Time between refuellings (min/max)
Fuel consumption (min/max)
Heatable room dimensions (min/max) *
Weight including packaging (min/max)
Smoke duct diameter (A male)
Air intake duct diameter (B male)
* The heatable room dimensions are calculated on the basis of
pellets with an lhv of at least 4300 kcal/kg and home insulation in
compliance with Italian law 10/91.
* It is also important to consider the position of the stove in the
room to be heated.
N.B.
1) bear in mind that external devices may cause interference.
2) caution: live parts. Servicing and/or inspections must be carried out by quali•ed staff.
ELECTRICAL SPECIFICATIONS
Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency (optional extra)
Protection on mains power supply
Electronic circuit board protection
SAFETY DEVICES:
THERMOCOUPLE:
On the smoke outlet. It measures the smoke temperature.
It controls the ignition, operating and shutdown stages according to
the parameters set.
AIR FLOW SENSOR:
On the intake duct. It trips when the "ow of combustion air is not
correct, therefore causing low pressure problems in the smoke
circuit.
SAFETY THERMOSTAT:
It trips if the temperature inside the stove is too high.
It stops pellet loading, thus causing the stove to go out.
15
kg
89,2
%
3,4/8,3
kW
7,5/20
hours
0,7/2,0
kg/h
115/230
m3
149/174
kg
80
mm
40
mm
230Vac +/- 10% 50 Hz
yes
150
W
400
W
infrared
2A, 250 Vac 5x20 Fuse
2A, 250 Vac 5x20 Fuse
- 16
-