djpower H-SW3000 Gebruikershandleiding - Pagina 12

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} djpower H-SW3000. djpower H-SW3000 16 pagina's. Aqua low fog machine

djpower H-SW3000 Gebruikershandleiding
Preparing Page
Standby Page
Working Status Pages
Setting Pages
< 8 >
Display
H-SW3000
AC-230V 50Hz
Heating Up
>>>>>>>>>>>>>>>
Ready 2 Low Fog
H-SW3000
Interval
600s
H-SW3000
Duration
300s
H-SW3000
Fog Output 100%
Fan Speed 100%
Fog Output
100%
Fan Speed
100%
Humidity
100%
Timer Interval
600s
Timer Duration
300s
DMX Address
512
Fluid Sensor
ON
Auto Run Last
Settings
YES
Keypad Tone
OFF
Language(语言)
English
Description
The machine is heating up.
Finished heating up, ready to
work.
Interval countdown of TIMER
mode
Duration countdown of TIMER
mode
Output status of VOLUME
mode
Press
or
to set fog
output of VOLUME mode
Press
or
to set fan speed
of VOLUME mode
Press
or
to set output
humidity of VOLUME mode
Press
or
to set timer
interval of TIMER mode
Press
or
to set timer
duration of TIMER mode
Press
or
to select DMX
starting address
Press
or
to
activate/deactivate fluid sensor
to turn on/off no-fluid-
protection function
Press
or
to set if the
machine will automatically run
previous setting when power
on again
Press
or
to turn keypad
tone ON/OFF
Press
or
to select the
language and save by ENTER
H-SW3000 USER MANUAL V1
Parameter Range
1-100%
1-100%
OFF/25%/50%/75%/100%
5-600s
5-300s
1-512
ON/OFF
YES/NO
ON/OFF
Chinese/English