1- Battery and AC monitoring: AC or Battery Fail condition will cause the common trouble input [C "FAULT" NC] to
report back to the FACP via input 1 and input 2. The common trouble input may also be used for other optional
supervisory monitoring.
To report AC and Battery Trouble connect the battery and AC Fail relay output shown in Fig. 3a, pg. 8 to the
common trouble input.
2- Dry contact input (C "DRY1" NC) (C "DRY2" NC) can be used to alarm output from an
addressable module (these inputs are unidirection and cannot report back to trigger module).
Connection to triggering devices must be made within 20ft. of distance and using conduit for wiring.
3- Auxiliary output (-AUX+) 24VDC at 1 amp max.
4- AC Local [NC, NO, C] should connect to the host control panel for local annunciation of the trouble condition.
Note: If common trouble input, terminals marked [C "FAULT" NC] are not used, these terminals must be
shorted (connect jumper) to remain inactive. For optional hookups see Fig. 3b, pg. 8.
Fig. 3
line
unswitched
L
120VAC
neutral
N
power mains
(non power-limited)
AC LOCAL
Battery and AC Supervision
BAT FAIL
Use separate knockout.
AC FAIL
DC
line
L
AC DELAY
neutral
N
AC LOCAL
stand-by battery
(non power-limited)
Fig. 3b
Battery and AC Supervision
BAT FAIL
Circuit (power-limited).
Use separate knockout.
AC FAIL
DC
AC
Unit should be tested at least once a year for the proper operation as follows:
AC DELAY
Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level
(26.2-26.4VDC recommended range).
Battery Test: Under normal load conditions check that the battery is fully charged. Check specified voltage
both at battery terminal and at the board terminals marked [+ BAT --] to ensure that there is no break in the battery
+
BAT
connection wires.
Fuses: Check input and output fuses on the power supply board, replace if necessary.
stand-by battery
Input fuse rating is 6.3 amp @ 250V, Output fuse rating is 15 amp @ 32V.
connection
Note: Maximum charging current is 1.5 amp.
(non power-limited)
Note: Expected battery life is 5 years; however, it is recommended changing batteries in 4 years or less if needed.
These circuits are used to monitor
AC and Bat Fail and will cause a
- 8 -
simultaneous trouble condition
to the FACP's IN1 and IN2
Optional Hookup Diagram:
Factory Installed
Board Interface
Cable
Factory Installed Board
Circuit (power-limited).
AC
These circuits are used to
monitor AC and Bat Fail
simultaneous trouble
condition to the FACP's
(Non-Supervised)
+
BAT
–
+ DC --
connection
–
+ DC --
Optional hookups:
Addressable
control module
trigger output
NC "DRY2" C
NC "DRY1" C
Addressable
control module
trigger output
Power-Limited Outputs 2.5 amp per output max. (total = 10 amp)
NC "DRY2" C
-- RET2 +
-- RET1 +
NC "DRY1" C
-- IN2 +
Interface Cable
Digital Communicator
or Local Annunciator
Dry output Contact
(Form "C" contacts)
FAULT
and will cause a
INP2 INP1
Factory Installed Board
OUT1 OUT2 OUT3 OUT4
Interface Cable
IN1 and IN2
+
--
4-wire Smoke
Detector
FAULT
INP2 INP1
Fire
Alarm
Digital Communicator
Control
OUT1 OUT2 OUT3 OUT4
Panel
or Local Annunciator
(FACP)
Dry output Contact
(Form "C" contacts)
Maintenance:
Magnetic
These circuits are used to
Door Holder
monitor AC and Bat Fail
and will cause a
simultaneous trouble
condition to the FACP's
IN1 and IN2
(Non-Supervised)
+
4-wire Smoke
Fire
Fire
Alarm
Alarm
Control
Control
Panel
Panel
(See Typical Application Diagram for device hook
Power-Limited Outputs 2.5 amp per output ma
-- RET2 +
-- RET1 +
-- LOOP1 +
-- IN2 +
-- IN1 +
-- OUT1 +
(See Typical Application Diagram for device hookup)
-- LOOP1 +
-- LOOP2 +
-- LOOP3 +
-- LOOP4 +
-- IN1 +
-- OUT1 +
-- OUT2 +
-- OUT3 +
-- OUT4 +
Addressable
control module
trigger output
Power-Limited Outputs 2.5 amp per output max.
NC "DRY2" C
-- RET2 +
-- RET1 +
NC "DRY1" C
-- IN2 +
OUT1
OUT3
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
OUT2
OUT4
RESET
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
+
DC
---
+
--
OUT1
OUT3
4-wire Smoke
IN>OUT SYNC
Detector
EOL Power
STROBE SYNC
TEMPORAL
Supervision Relay
INPUT SELECT
(Not Supplied)
OUT2
OUT4
IN>OUT SYNC
STROBE SYNC
TEMPORAL
EOL Resistor
INPUT SELECT
Trouble Memory
from FACP
Reset Button
FAULT
INP2 INP1
OUT1 OUT2 OUT3 OUT4
--
+
--
4-wire Smoke
Detector
Detector
(total = 10 amp)
-- LOOP2 +
-- LOOP3 +
-- OUT2 +
-- OUT3 +
Fig. 3a
-- AUX2 +
AC
-- AUX1 +
(See Typical Application Diagram for devic
-- LOOP1 +
-- LOOP2 +
-- IN1 +
-- OUT1 +
-- OUT2 +
Magnetic
Door Holder
Fig. 3c
RESET
+ DC ---
OUT1
OUT3
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
OUT2
OUT4
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
+
DC
---
+
--
4-wire Smoke
+
--
4-wire Smoke
Detector
Detector
AL1042ULADA
-- LOOP4 +
-- OUT4 +
-- LOOP3 +
-- LOOP4 +
-- OUT3 +
-- OUT
RESET
EOL Powe
S
Supervision R
(Not Supplie