DMX-Buffer & DMX-Clarify Specification
Mechanical
Housing: metal desktop case
y
Material: Steel
y
Overall dimensions: 88 mm (W) x 58 mm
y
(H) x 42 mm (D)
Mass: 0.2 kg
y
Mounting: Free-standing or surface mount
y
Country of manufacture: UK
y
Environmental
Operating temperature: 0°C to 40°C
y
Storage temperature: -10°C to +50°C
y
Operating relative humidity (max): 80% non-
y
condensing
IP rating: IP20 indoor use only
y
Certification: CE, WEEE, RoHS
y
Warranty: 2-year (return to base)
y
Power & Electrical
Input voltage: 9 VDC
y
Input connector: DC jack (1 no.)
y
Input power (max): 5 W
y
Duty cycle: 80% @ 25°C
y
DC fuse: internal resettable fuse for control
y
electronics
Data Connections
Input connection: 5-pin XLR male or (DMX-
y
Buffer only) RJ45 Ethercon (1 no.)
Output connection:5-pin XLR female or
y
(DMX-Buffer only) RJ45 Ethercon (1 no.)
DMX-Protect Specification
Mechanical, Environmental, Data Connections,
Control
As above
y
Power & Electrical
Passive
y
DMX input
Protected against continuous connection to
y
425 VAC
Protected by gas discharge from static
y
electrocution and lightning strike above 420
VDC
DMX-Buffer, DMX-Clarify & DMX-Protect User Guide
DMX Input
Input mode: Ground referenced
y
Input isolation: n/a
y
Input ESD protection: 12 kV
y
Input voltage protection: n/a
y
DMX Output
Output mode: Buffered
y
Output isolation: n/a
y
Output ESD protection: 10 kV
y
Output voltage protection: n/a
y
Control
Input Protocols: DMX512, DMX512 (1990),
y
DMX512-A, RDM V1.0 (E1.20 - 2006 ESTA
Standard)
Output Protocols: Same as input, except
y
that DMX-Clarify does not output RDM
LED Indication
Power / Data
y
Package Contents
DMX-Buffer (XLR or RJ45) or DMX-Clarify
y
User guide
y
Accessories (not included)
PSU-9-1.5-DCJ
y
DMX output
Protected against continuous connection to
y
425 VAC
Protected by gas discharge from static
y
electrocution and lightning strike above 420
VDC
LED Indication
Not applicable
y
Package Contents
DMX-Protect
y
User guide