Front
Two dual colour indicators are provided:
Panel
Indicators
Data:
Power:
DMX512
The DMX512 input is connected to the male 5 pin XLR on the
Input
left of the front panel. The female 5 pin XLR provides a
passive loop through such that multiple DMX512 receivers can
be connected to the same signal. When the Rack-Split RDM is
to be used at the end of a DMX512 cable, a termination
connector should be fitted to the loop through.
The DMX512 input is optically isolated from the outputs and
mains earth.
DMX512
The DMX512 outputs are provided on eight 5 pin XLR
Output
connectors. Each output is independently buffered.
Cable connection for both input and output is as follows:
Each output is capable of driving 32 DMX512 devices.
It is not necessary to terminate unused outputs.
Artistic Licence Engineering Ltd.
Green: Indicates that DMX512 data is flowing from
input to all outputs (normal operation).
Red: Indicates that RDM data received by the
outputs is being returned to the controller.
Red: Indicates good power and normal operation.
Flashing: Indicates that a connected RDM device is
jabbering (returning unwanted data continuously).
Return data from this output will be disconnected.
Pin 1
Protective ground
Pin 2
Data complement
Pin 3
Data true
Pin 4
Not used
Pin 5
Not used