Alula RE107 Handmatig - Pagina 2

Blader online of download pdf Handmatig voor {categorie_naam} Alula RE107. Alula RE107 4 pagina's. Outdoor door/window sensor

Make sure to align the alignment marks on the sensor and magnet
when mounting. Finish by latching the sensor to the mounting
plate and tightening the cover-securing screw to secure the sensor
in place.
Removal Tamper
with rubber washer through the removal tamper screw hole in the
base and into the mounting surface. Remove the battery for access
to the removal tamper screw hole.
External Contacts
the back of the enclosure. A thinned area in the enclosure must be
punched out with a screwdriver to allow the wires through. After
routing and connecting the wires, reseal the hole with silicone
caulk.
• Do not use end-of-line resistors.
• Wire contacts to one or both outside terminals using the
center terminal as a shared common.
• The sensor defaults to use normally closed contacts (alarm
condition when contact is open).
• To reprogram external inputs, set both externals to the
desired non-alarm state and restart (remove and reinstall
battery) the device 3 times while holding the tamper
switch.
Pro Tips
Metal installs should include pre-drilling holes before using
screws to secure the mounting plate and magnet.
Wireless performance is optimized when mounted near the top
of the gate or door in a vertical orientation.
is implemented by screwing the provided screw
can be installed by routing the wires through
Removal tamper
screw hole
Thinned area for external
contact wires