Alula RE618 Snelstarthandleiding - Pagina 2
Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Alula RE618. Alula RE618 2 pagina's. Flood & temp sensor connect+ encrypted
Pro Tips
The cover can be removed without removing the wall clip.
Both titanium probes must be in the same puddle for the it to detect water.
Tamper detection depends on how the sensor is installed.
• Secured to wall: Tamper is indicated when lifted off the clip.
• NOT secured to wall: Tamper is indicated when the cover is removed.
When changing the batteries replace both with new batteries.
Specifications
Physical
Housing Dimensions
Weight with Batteries
Mounting Fastener
Environmental
Operating Temperature
Maximum Humidity
Water Resistance
Sensor Specifications
Frequency
Replacement Batteries
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Temperature Accuracy
Certification
RE618
RE618-CE
WARRANTY
Alula will replace products that are defective in their first five (5)
years.
TRADEMARKS
Alula and Connect+ are trademarks owned by Alula Holdings, LLC.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes:
(1) L'appareil ne doit pas produire de brouillage, et
(2) L'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
IC: 8310A-RE318
2.43 x 2.48 x 1.17 inches (6.2 x 6.3 x 3.0 cm)
1.34 ounces (38 grams)
#6 screw (not provided)
32°F to 120°F (0°C to 49°C)
85% non-condensing relative humidity
IP67 rated (waterproof for over 30 minutes at 1 meter depth)
433.92 MHz
Two Panasonic CR2032
10 years
3.0 VDC (Nominal) 2.3 VDC (Low)
20 mA (Maximum) 0.5 uA (Quiescent)
Cover Tamper, Wall Tamper, Low Battery, Supervision
+/- 2°C
FCC, IC, RCM
EN60950-1, EN300 220, EN301 489
Specifications subject to change without notice.
47-0028-08 • REV C • 2018-03-06
Tech Support Line • (888) 88-ALULA • (888) 882-5852
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by Alula could void
the user's authority to operate this equipment.
FCC ID: U5X-RE318
CE DECLARATION OF CONFORMITY
Hereby, Alula declares that this RE618-CE is in compliance with the
essential requirements and other relevant provisions of directive
1999/5/EC.
(This declaration can be translated to other languages via a myriad
of translation tools found on the Internet.)
alula.net
01