Controller Specification
The variable "n" is adopted as a multiplying factor when calculating parameter voltages, the rule for
"n" is listed as: if battery system voltage is 12V, n=1; 24V, n=2; 36V, n=3; 48V, n=4.
For example, the equalize charge voltage for a 12V FLD (Flooded) battery bank is 14.8V*1=14.8V. The
equalizing charge voltage for a 24V FLD (Flooded) battery bank is 14.8V*2=29.6V.
Parameter
Model No.
Battery System Voltage
No-load Loss
Max Solar Input Voltage
Rated Solar Charge Current
Max Solar Input Power
Light Control Voltage
Light Control Delay Time
Max Load Output Current
Operating Temperature
IP Protection
Net Weight
Communication Port
Operating Altitude
Controller Dimension
Parameter
Battery Types
Equalize Charge Voltage
Boost Charge Voltage
Float Charge Voltage
Boost Charge Recovery Voltage
Over-discharge Recovery Voltage
Over-discharge Voltage
AutoTemperature Compensation
CEP400
12V/24V
Auto (FLD/GEL/SLD)
Manual (Li/User)
12ma (12V), 10ma (24V)
<100Voc
40A
600W/12V
1200W/24V
IP32
2.0 kg
245*180*82.5
mm
FLD
SEL
14.8V*n
14.6V*n
14.6V*n
14.4V*n
13.8V*n
13.2V*n
12.6V*n
11.1V*n
-3mV/2V/℃
18
Value
5V*n
10s
20A
-35ºC ~ +45ºC
RS485
≤ 3000 meters
Battery Parameters
GEL(default)
USER(adjustable)
--
Default
14.2V*n
Default: GEL
Default: GEL
Default: GEL
Default: GEL
Default: GEL
Default: GEL
IP32
3.0 kg
280*210*90 mm
LI (adjustable)
--
Default: 14.2V*n
--
--
--
Default: 11.1V*n
--