CVap HBB Series Gebruikershandleiding - Pagina 5

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} CVap HBB Series. CVap HBB Series 8 pagina's. Hold & serve drawer

CVap HBB Series Gebruikershandleiding

HOW YOUR CVAP WORKS

ON/OFF SWITCH
WARMUP
FOOD TEMP
FOOD TEXTURE
CONVERT °F to °C or °C to °F
CLEAN DAILY
CABINET RESET BUTTON
(
INTERNATIONAL UNITS ONLY)
TECHNICAL SERVICE AND
TROUBLESHOOTING
Displays
Temperature or Time
selection.
NEED TO CONTACT US?
www.winstonindustries.com • E-mail [email protected] | Mail 2345 Carton Drive | Louisville, KY 40299 USA
HBB HOLD & SERVE DRAWER
Energizes control and evaporator and air heat systems. Program mode
initiated if the "1" key is shortly held and released during toggle on. Fill
with potable water prior to turning on.
Display indicates Heat until set points are reached, then LoAd.
Press Food Temp UP/DOWN keys () to increase/decrease
temperature in 2°F (1°C) steps while in program mode.
Press Food Texture UP/DOWN keys () to increase/decrease the
differential (temperature increase above food temp setting) in 2°F (1°C)
steps while in program mode.
Short press the F/C key (indicated below) while in program mode. The
default temperature display can be changed with a 4 second press
of the F/C key. Choose between AF for air temp in Ferenheit, AC for
air temp in Celcius, EF for evaporator temp in Farenheit and EC for
evaporator temp in Celcius.
Stainless steel can corrode if soil is allowed to stand. Clean daily.
Remove loose parts and wash in sink. Rinse well. Do not use Chlorine.
(Located behind drawer.) Resets the thermostat in the event that
the High Limit Thermostat trips. To reset, allow the drawer unit to cool
to below 250°F (121°C). Press the High Limit Reset button. If the High
Limit Thermostat trips frequently, call a service technician for repair.
If you have questions about your CVap appliance, please contact your
Corporate Office, local distributor, or Winston's Customer Service Center.
internet: www.winstonindustries.com
telephone: +1 502.495.5400 | +1 800.234.5286
Sets evaporator temperature
to control food temperature
90-200°F (32-93°C) while in
program mode.
Phone 1.800.234.5286 | 1.502.495.5400 | Fax 1.502.495.5458
(8:00 a.m. - 5:00 p.m. EST, Monday through Friday)
Toggle
between
Fahrenheit
and Celsius
5
Changes
values of
selected
timer, Food
Temp, or
Food Texture.