ARTRED AR50 Bedieningshandleiding - Pagina 8
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} ARTRED AR50. ARTRED AR50 12 pagina's.
required.
Move the machine to the parking place.
12.
3.1Battery Charging and Maintenance
Safety regulations for handling acid batteries
Park the scrubber securely before carrying out any work on the batteries.
Maintenance personnel : Batteries may only be charged, serviced or replaced by trained
personnel .The present operator manual and the manufacturer 's instructions concerning
batteries and charging stations must be observed when carrying out the work.
Fire protection :
Smoking and naked flames must be avoided when working with batteries.
Wherever a scrubber is parked for charging there shall be no inflammable material or operating
fluids capable of creating sparks within 2 meters around the scrubber.
The area must be well ventilated.
Fire protection equipment must be provided.
Protection against electric shock:
Battery has high voltage and energy.
Do not bring short circuit.
Do not approach tools to the two poles of the battery,which can cause the sparkle.
Charging the battery
To charge the battery, the scrubber must be parked in a closed and properly ventilated room.
When charging, the tops of the battery cells must be exposed to provide sufficient ventilation.
Do not place any metal objects on the battery.
Before charging, check all cables and plug connections for visible signs of damage.
Before start and finish charging to make sure power is turn OFF.
It is essential to follow the safety regulations of the battery and charging station manufacturers.
Charging step:
1.Place the charger and the machine in a well-ventilated place.
2.Turn off the power of the machine.
3.Insert the DC output terminal of the charger into the charging port of the machine.Must be
sure the charger terminal engaged with charging port completely.
4.Plug the AC power cord of the charger into a well-grounded power outlet.
5.When charging is completed, first unplug the ice dragon connected to the AC power supply,
and then unplug the output end of the charger from the machine.
Warning:
1. Move the machine to the place with good ventilation for charging.
battery releases hydrogen. Please be away from spark or open fire. The battery cabin must be kept
open when charging.
2. Stop and place the machine on the level ground and turn the key to the close position.
3. Before charging, check the electrolyte level in each battery unit.
For safety: Please wear protective gloves and eye protectors when treating the battery
and battery wiring when repairing the machine. Avoid contacting the battery liquid acid.
When charging, please open the side of the waste water tank to facilitate ventilation.
4. Plug the AC (alternating current) power cord of the charger to the power socket with sound
grounding.
5. Plug the DC (direct current) power cord of the charger to the battery charging socket behind the
waste water tank.
- 7 -
f
ire or explosion hazard. The