PACKAGED ELECTRONIC CIRCUIT
Element
U8
U9
U10
U11
U12
REL1
REL2
LED1
J1
J2
J3
J4
J7
J8
J9
J10
J11
J12
Y
If security sensors are not plugged in (J10 and J11 adapters), jumpers must be installed
(pic. 2). If a security sensor is plugged in, remove the jumper.
6
6
Safety device T6.3А
ATTENTION: Use safety devices filled with glass sand!
Transformer
2А safety device
Relay
The LED which signals the valve's operational status.
It is on if power voltage is supplied to the valve
Jumper for selection of safety sensor type: PNP or NPN (transistor output)
Control button 2 adapter (pic. 1)
Network adapter (pic. 3)
Protection grounding adapter
Jumper adapter depending on the supply voltage.
If supply voltage is 400 V, the jumper must be installed as in pic. 2
Line circuit breaker 1 adapters (pic. 1, pic. 2).
The plug of 015 3P + N + E 16A / 6h type is used for network connection.
The socket must be of the same type for the plug using it
The adapter of a hydraulic unit valve (pic. 5) and sectional doors position
sensor (pic. 6). Security sensor supply voltage is 24 V DC. If the security sensor
has signaled (sectional doors are closed), the hydraulic unit electric motor
must be turned off and the platform must be blocked
The adapter of a hydraulic unit electric motor (pic. 4) and stop-motion
sensor (NC)
LED1 jumper. The LED will be on if the jumper is installed.
If the jumper is removed, the LED is off.
Description
CONNECTION AND OPERATIONAL MANUAL. CONTROL UNIT CUL01
Table 2. Circuit elements list