Alva GCS05 Snelstarthandleiding - Pagina 7

Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Alva GCS05. Alva GCS05 12 pagina's. High pressure gas cooker two burner automatic stove

Alva GCS05 Snelstarthandleiding
7. Attach the high pressure cylinder connector to the gas valve
outlet. Hand fasten in a clockwise direction to ensure a gas
tight seal.
8. Perform the LEAK TEST.
Wall
100cm
15cm
Wall
15cm
15cm
Fig.10
FITTING AND CHANGING THE GAS CYLINDER
1. Before connecting the appliance to a gas cylinder,
always ensure that the rubber seal on the High Pressure
Cylinder Connection is in position and in good condition,
and blow out any dust from the cylinder opening to prevent
possible blockage of the jet.
2. Ensure that the gas cylinder is fitted or changed in a
well-ventilated location, preferably outdoors, away from any
source of ignition, such as naked flames and away from
other people.
3. Make sure that the gas cylinder is kept upright at all times,
screw the tank adaptor onto the cylinder until it is fully en-
gaged. Hand-tighten only.
4. Never store the cylinder on a stove surface. It is best
practice to store it on the floor in a position wher it cannot be
tampered with.
5. If there is a leak on your appliance (smell of gas), take it
outside immediately into a well-ventilated flame free location
where the leak may be detected and stopped.
6. When removing a gas cylinder (e.g. to change cylinders),
firstly close the cylinder valve and then the appliance valve,
making sure the flame is extinguished, before unscrewing
the tank adaptor. Re-fit the High Pressure Cylinder
Connection to a full cylinder following the same precautions
as above.
9. Locate properly. Maintain a
safe installation proximity. See
Fig.10
Wall
Wall
5
FOR YOUR SAFETY
IF YOU SMELL GAS
Turn off the gas
supply at the
bottle.
Extinguish all
naked flames.
DO NOT operate
any electrical
appliances.
Ventilate the
area.
Check for leaks
(see LEAK TEST)
If odour per-
sists, contact
your dealer or
local gas supplier
immediately.
Any LP Gas cylinder
not connected for use
must not be stored in
the vicinity of this or
any other appliance.