FLASHBACK (FLAME IN BURNER TUBE)
In the event of flash back whilst the appliance is in use, turn all
the controls and the cylinder valve to the 'OFF' position. Wait 5
minutes before attempting to relight the appliance.
If the problem persists, check for blocked venturi ports by remov-
ing the burner and cleaning with compressed air or with a pipe
cleaner. Replace burner correctly.
If problem persists do not try to rectify the problem yourself as
this could result in serious injury and/or property damage.
Store the appliance in a clean and dry environment. Do not store
your gas cylinder indoors. Store in a well ventilated area away
from direct sunlight or an electrical source.
After using the unit,
1.
Shut off the water (bag) tap
2.
Turn the power off and close the gas supply at the cylinder
valve.
3.
Wait for about 6 minutes to let the water heater to cool
down. Do not touch it until it has cooled down.
4.
Disconnect the water supply hose ( reverse of assembly).
5.
Disconnect the gas cylinder ( reverse of assembly).
6.
Push the tap back to cover position
7.
Take the batteries out of the unit.
8.
Drain all water from the unit.
DISASSEMBLY
STORAGE
Fig.J
9