Alvarion BreezeACCESS LB Release Release - Pagina 3
Blader online of download pdf Release Release voor {categorie_naam} Alvarion BreezeACCESS LB. Alvarion BreezeACCESS LB 3 pagina's. Breezeaccess lb series
Ook voor Alvarion BreezeACCESS LB: Brochure & specificaties (4 pagina's)
automatically selects the speed through auto-negotiation with either the host
computer/server or router/switch.
FD/Col LED
The FD/Col LED lights solid green when the LAN connection is operating in Full
Duplex mode and flashes when collisions are detected on the Ethernet port.
Compatibility and Interoperability
LB IDU H/W version B1 must have Software Release 1.32 or Higher
The LB IDU hardware version B1 is not compatible with any software release prior to
version 1.32.
LB software version 1.32 Option Key must be Entered Prior to Operation
For any LB system having software release 1.32 or higher installed, an options key
must be entered before operating the system. Prior to entering the key, the system will
be unable to establish the wireless link. Contact the technical support department for
instructions on how to obtain the options key.
Master Setting must be Configured Prior to Operation
The LB software version 1.32 is over-the-air compatible with LB systems running
release 1.21 software. All PTP links that include at least one system running software
release 1.32 or higher must be configured with one of the two systems configured as
'master'.
Important: Only one LB system in a wireless link must be set for 'master' mode.
Each release 1.32 point-to-point link is comprised of a master-end LB system and a
remote-end LB system. The master-end system establishes and manages the bi-
directional data link with the remote-end system. The remote-end system receives and
sends data under the control of the master-end system.
The Master selection is available in the web interface Configure System screen. Check
the Master tick box to configure a system to operate as the master system (base
stations). Uncheck the Master tick box to configure the second system to operate as
the remote-end (subscriber station).
MIB Updated
An updated MIB file has been released to support these features.
Document update
Manuals were updated to reflect the new features.
Upgrading Notes
An upgrade package to version 1.32, including additional upgrade instructions and the updated
documentation can be obtained from Alvarion web site's technical support area.
Important Notes
SYNC LED
This function is not supported in the current release.
BreezeACCESS LB
Software Version 1.32
Release Note
Page 3 of 3