Troubleshooting Chart
Symptom
Pump will not start or
run
Pump starts and stops
too often
Pump will not shut off
or thermal protector
turns off
Pump operates but
delivers little or no
water

Limited Warranty

For (One year on Models BSPF33, BSPF50, and BSC333HH) (Three years on Models BCS33, BCS50, and BCS50-2) (Five years
on Models SSBCSF33-2, SSBCS33, SSBCSF50-2, SSBCS50) from the date of purchase, Blue Angel™ will repair or replace, at its
option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps ("Product") found upon examination
by Blue Angel™ to be defective in materials or workmanship. Please call Blue Angel (1-888-636-6628) for instructions or
see your dealer. Be prepared to provide the model number when exercising this warranty. All transportation charges on
Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect,
improper installation, improper maintenance, or failure to operate in accordance with Blue Angel's™ written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO (ONE YEAR ON MODELS BSPF33, BSPF50, AND BSC333HH)
(THREE YEARS ON MODELS BCS33, BCS50, AND BCS50-2) (FIVE YEARS ON MODELS SSBCSF33-2, SSBCS33,
SSBCSF50-2, SSBCS50) FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR
ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations
of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you
specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Blue Angel™
or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of
profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of
capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer's customers
for such damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST
send a copy of the purchase receipt along with the material or correspondence. Please call Blue Angel™ (1-888-636-6628)
for return authorization and instructions.
DO NOT MAIL THIS FORM TO BLUE ANGEL. Use this form only to maintain your records.
MODEL NO. ____________________
ATTACH YOUR RECEIPT HERE
www.blueangelpumps.com
Possible Cause(s)
1. Blown fuse, tripped breaker
2. Low line voltage
3. Defective motor
4. Defective float switch
5. Impeller bound
6. Float obstructed
7. GFCI tripped
1. Back-flow of water from piping
2. Faulty float switch
1. Float obstructed
2. Obstacle in piping
3. Defective float switch
1. Low line voltage
2. Clogged inlet
3. Plugged impeller
4. Obstacle in piping
5. Check valve installed backwards
6. Too many appliances on circuit
SERIAL NO. ____________________
BCS, BSPF, and SSBCS Series
Corrective Action
1. If blown, replace with proper sized fuse or reset breaker.
2. If voltage is under 108 volts, check wiring size.
- DO NOT USE AN EXTENSION CORD
3. Replace pump
4. Replace float switch
5. If impeller will not turn, remove housing and remove
blockage
6. Make sure float moves freely up and down float rod
7. Reset GFCI Circuit. If GFCI continues to trip, replace pump.
1. Install or replace check valve
2. Replace float switch
1. Make sure float move freely up and down
2. Remove pump and clean pump, check valve and piping
3. Replace float switch
1. If voltage is under 108 volts, check wiring size
- DO NOT USE AN EXTENSION CORD
2. Clean inlet screen
3. Clean out impeller
4. Remove pump and clean pump, check valve and piping
5. Reverse position of check valve
6. Install pump on dedicated circuit.
IMPORTANT: Do not use an extension cord to power pump