2.8. Ignition Detection
Electrical Characteristics of Ignition Detection
Logical status
Active
Inactive
IGN (Pin3) is used for ignition detection. It is strongly recommended to connect this pin to
ignition key "RUN" position as shown above.
An alternative to connecting to the ignition switch is to find a non-permanent power source
that is only available when the vehicle is running, for example, the power source for the FM
radio.
IGN signal can be configured to start transmitting information to the backend server when
ignition is on, and enter the power saving mode when ignition is off.
2.9. Digital Inputs
There are three general purpose digital inputs on NxtG-V. They are all negative triggers.
Logical status
Active
Inactive
The following diagram shows the recommended connection of a digital input.
Electrical characteristics
5.0V to 32V
0V to 3V or open
Typical Ignition Detection
Electrical Characteristics of the Digital Inputs
Electrical characteristics
0V to 0.6V
Open