CLIVET WSAT-23.620 Installatie-, Bedienings- en Onderhoudshandleiding - Pagina 4

Blader online of download pdf Installatie-, Bedienings- en Onderhoudshandleiding voor {categorie_naam} CLIVET WSAT-23.620. CLIVET WSAT-23.620 14 pagina's. Air-cooled water chiller

CLIVET WSAT-23.620 Installatie-, Bedienings- en Onderhoudshandleiding
$&2867,& &21),*85$7,21 (;75(0(/< /2: 12,6( (1
*(1(5$/ 7(&+1,&$/ '$7$
Standard supply
Cooling capacity (1)
kW 447.7
Compressor input
kW 169.8
Total input power
kW 185.2
Compressor type
Compressors No.
Nr
Nominal power (C1)
HP
Nominal power (C2)
HP
Nominal power (C3)
HP
Capacity control steps
Nr
STD
Refrigerant circuits
Nr
Type
Number
Nr
Water flow
l/s
Pressure drops
kPa
Water volume
l
Front surface
m
Tipo ventilatori
Numero ventilatori
Nr
Portata aria standard
l/s
Water fittings
(1) data referred to the following conditions:
23(5$7,21 /,0,76 &22/,1*
6,]H
Max. air inlet
1 C
temperature
2 C
3 C
4 C
Min. air inlet
temperature
5 C
6 C
Max water inlet
7
temperature
Min water outlet
8 C
temperature
9 C
Note: In any case, the unit should never be exposed to or operated, transported and/or stored at temperatures below -10 C.
condenser coil thus worsening the operating limits of the unit (see limits with air speed at 0,5 m/s & 1 m/s). In order to avoid such
situation, windbreak barriers are necessary. The minimum ambient temperature is given for units equipped with low ambient
control or with ECObreeze fans.For standard unit without these options, this value is of about 18 C with still air and unit operating
at full load.
(1) unit at full load
(2) capacity-controlled unit (automatic capacity control)
(3) unit at full load external exchanger air 35 C
(4) unit at partial load (automatic capacity control) air to external exchanger 35 C
(5) unit at partial load (automatic capacity control) air to external exchanger = 0.5m/sec
(6) unit at partial load (automatic capacity control) air to external exchanger 35 C
(7) external exchanger air intake 35 C
(8) Standard Version external exchanger air intake 35 C
(9) Low temperature version external exchanger air intake 35 C
Fluid with ethylene glycol of 40%
4
V
508.2
594.1
197.7
218.5
215.6
235.7
2
2
2
100
130
130
130
130
150
-
-
-
6
6
6
2
2
2
1
1
1
21.4
24.3
28.4
31
27
34
114
222
206
2
29.4
29.4
35
10
12
10
35300 39900 44400 50615 56530 56530 56530 72800 78700 82900 78700 82900
"
6
8
8
internal exchanger water = 12/7 C
room temperature = 35 C
42.5
42.5
43
45
45.5
46
-10
-10
-10
-2
-4
-6
10
10
8
18
17
17
C
21
21
21
6
6
6
-8
-8
-8
400/3/50
671.5
720.6
787.5
867.5
243.1
284.6
323
358.8
263.9
309
349.6
383.8
2
2
2
150
180
180
220
150
180
220
220
-
-
-
6
6
6
2
2
2
Tube bundle
1
1
1
32.1
34.4
37.6
41.4
39
44
58
41
206
184
222
252
35
35
35
35
axial
12
14
14
14
8
8
8
42.5
42
41
46.5
46
45
-10
-10
-10
-10
-6
-5
-5
8
8
8
16
17
17
21
21
21
6
6
6
-8
-8
-8
. Any wind condition can let air pass through the
1008
1085
1137
364.2
430
464.6
397.2
469.8
504.6
2
3
3
3
150
180
180
150
180
180
-
150
180
220
6
9
9
9
2
3
3
3
1
1
1
1
48.2
51.8
54.3
54
74
58
252
295
462
54
54
54
18
20
22
8
8
8
8
41
42
42
41
45
46
45.5
46.5
-10
-10
-10
-5
-7
-6
-6
8
9
9
9
16
16
16
17
21
21
21
21
6
6
6
6
-8
-8
-8
-8
1244
1312
507.8
544.4
550.7
592.7
3
3
180
220
220
220
220
220
9
9
3
3
1
1
59.4
62.7
80
90
423
423
54
54
20
22
8
8
41
41
45.5
45
-10
-10
-5
-5
8
10
18
18
21
21
6
6
-8
-8