Setting Function List
Display
Setting Fuction (Default Value)
(1)
Counter ON/OFF Setting
(2)
Count
(3)
Minimum Revolutions*
Maximum Revolutions*
(4)
Work Reset Timer
(5)
Reverse Count Timer
(6)
System Setting
(7)
Over Time/Short Time
(8)
Accumulated Counter
(9)
No Error Time for Double Fastening
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
HIOS BLG Series: BLG-BC2
Operational Manual
Symbol
| Phone: (
44110-3898
888) 486-6163
Setting Description
ON: When selected, the counter function is available.
OFF: When selected, it is used as a normal screwdriver. The display is also OFF.
The screw fastening count value is set. Setting Range: 1 to 99
The minimum numbers of motor revolutions
Display range: 000-999; Setting range : 000-999
* Hundreds place is not displayed.
Fx. Minimum number is 110 but only 10 is displayed on the screen
The maximum numbers of motor revolutions
Display range: 000-999; Setting range : 000-999
* Hundreds place is not displayed.
Fx. Maximum number is 120 but only 20 is displayed on the screen.
Refer to "Value Setting for Each setup functions"
If the detected pulse is smaller than the minimum or larger than the maximum, the
red LED light (Fail) turns on. If the detected pulse is larger than the minimum and
smaller than the maximum, the green LED light (Pass) turns on.
The buzzer sound time period after the work is completed is set. Setting Range: 0.0 to
3.9 seconds. Note: Set it based on the reverse count timer set value.
The time period until the reverse count is performed is set. Set the work reset timer
operation time based on the time period up to when the reverse count is performed.
Setting Range: 0.1 to 1.0 seconds. Note: It is available when the "Reverse Count
Enable" has been set in the system setting.
Each Buzzer or Reverse Count Enable/Disable is set up. The setting is performed with
a combination of the tens digit and single unit digit.
Tens Digit
0 : Buzzer Enable/Reverse Count Enable
1 : Buzzer Enable/Reverse Count Disable
2 : Buzzer Disable/Reverse Count Enable
3 : Buzzer Disable/Reverse Count Disable
Units Digit
2 : Torque Up Buzzer Disable
3 : Torque Up Buzzer Enable
This sets whether or not the Over Time/Short Time error is detected.
"0 : When selected, neither Over Time or
Short Time Error is detected."
1 : When selected, only the Short Time Error is detected.
2 : When selected, only the Over Time Error is detected.
3 : When selected, both Over Time and Short Time Error are detected.
The Total count of the screw fastening operations is displayed. For the total count, all the
fastening operations are counted regardless of whether the counter is ON/OFF.
Display:
Units Digit:
Tens Digit:
Units Digit: Numbered in multiples of 100,000 shots
Tens Digit: Numbered in millions of shots
No error time can be set with three bards + values in order to avoid unnecessary
errors during double fastening. This setting is enabled only when fastening is done
properly. Display range: 0.0-9.9, Setting range: 0.0-9.9
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com
216) 481-4519