EXAMPLES FOR GROUPING
*Follow These Examples to Achieve maximum MPPT performance*
Battery Bank
Max.PV Panel
Volt
Voltage Range
12V
30-100V
50-140V
24V
36V
70-140V
48V
100-140V
Note: Solar panels should be grouped in such a way that the Open
Circuit Voltage (Voc) of the panels connected in series should not
exceed the Maximum panel voltage men�oned above for each
ba�ery bank!
NEON-30 Vers.6
OF PV PANELS
Examples for Grouping
PV Panels in Series
(Voc)
1) 21 voc(100w panel)x4panel
in series=84Voc=400w
2) 47 Voc(375w panel) x1
1) 47 Voc( 375w panel) x2panel
in series= 94Voc=750w
2) 21 voc(150w panel)x5panel
in series=105Voc=750w
21 Voc(100w panel)x6panel in
series=126Voc=600w X 2 strings
in parallel=1200w
36 Voc(260w panel)X3panel in
series =135Voc=780w X 2
strings in parallel=1560w
06
Max.PV Panels
Applicable
in Watts
500W
1000W
1500W
2000W