5.
Attach the pump (A) to a sturdy base (table, board, etc.) to prevent it from tipping over. Make sure the
hoses are as straight as possible.
WARNING: This pump CANNOT be submersed in water, and the motor
CANNOT get wet at all. Getting the motor wet could cause
electrocution, which could lead to serious injury or death!
NOTICE: DO NOT coil or kink the hose
6.
To operate, plug the pump (A) into a GFCI outlet.
NOTICE: This pump can be very loud when plugged in. THIS
IS NORMAL. Once water begins to pump, the noise will
dissipate. When the water level has been reduced to
approximately 1/8 in., you MUST UNPLUG THE PUMP. DO
NOT RUN DRY. The pump will be EXTREMELY LOUD when
the pump is no longer pumping water.
NOTICE: If water is not pumped in 30 seconds, unplug the
power cord and check the connection on the two ends of the
inlet hose to make sure there are no air leaks. Then, add
water into the inlet again and repeat the process.
Problem
1. Blown fuse
2. Tripped breaker
Pump does
3. Plug disconnected
not start or
4. Corroded plug
run
5. Motor overheated
1. Air leak in suction line
2. Impeller clogged
Pump doesn't
3. Impeller worn or damaged
prime
4. Impeller dry
1. Hose kinked or coiled
2. Strainer or hose blocked
Flow rate is
3. Discharge hose too long
too low
4. Worn impeller
PREPARATION
TROUBLESHOOTING
Possible Cause
5
6
A
C
Corrective Action
1. Replace fuse
2. Reset breaker
3. Secure plug
4. Clean plug prongs
5. Unplug the power and wait for 30
minutes,then plug in the power cord
1. Repair suction line by tightening
hose connection
2. Remove blockage
3. Replace impeller
4. Add water to the pump inlet
1. Straighten hose
2. Clean strainer or hose
3. Shorten the hose (50 ft. max)
4. Replace the impeller
A
C
B
B