Ashcroft GC35 Installatie- en onderhoudshandleiding - Pagina 9

Blader online of download pdf Installatie- en onderhoudshandleiding voor {categorie_naam} Ashcroft GC35. Ashcroft GC35 20 pagina's. Heavy duty digital pressure sensor
Ook voor Ashcroft GC35: Snel aan de slag Instructies (4 pagina's), Snel aan de slag Instructies (4 pagina's)

Ashcroft GC35 Installatie- en onderhoudshandleiding

5. NOISE PREVENTION

Power Supply
The pressure display can fluctuate and provide incorrect output if noise is present in the
power supply/wires. Care should be taken to keep the GC35 power supply wires from high
voltage lines and use a power line with a high noise rejection ratio.

6. STORAGE

Store in a location in compliance with the environmental rating of the unit and within –20 to
+70°C (–4 to 158°F). Avoid direct exposure of the display to Sunlight.

7 . MAINTENANCE

Although this is a solid state device, it is recommended that a visual inspection be conducted
twice a year along with regular zero adjustment if necessary.

8. MENU NAVIGATION

Functions
Please Note: Do not use sharp objects to press the keys as this can puncture and damage
the panel.
Collector/switch 1
LED operation indicator
(OUT 1)
4 Digit, 8mm
LED display
MODE key
DOWN key
Collector/switch 1
LED operation
indicator (OUT 2)
Setting mode
LED operation
indicator (SET)
UP key
9