6.0 Setting
A
A=>downward and selection of menu items
B=>upward and selection of menu items
A+B=>select menu item to set or to confirm setting
6.1 Decimal Point
Press B key until - d P - is displayed
=>A+B menu item to set:- -.- -
=>B or A for up and down:- - -.-
=>A+B to confirm setting and return to menu item - d P –
6.2 Zero Point (value to be displayed at 4 mA)
Press B until - Z P 4 is displayed
=>A+B menu item to set:- 0.0 0 for example (0 psig)
=>B or A for up and down
=>A+B to confirm setting and return to menu item -Z P -