Ashley Signature Design P016-772 Gebruikershandleiding - Pagina 7
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Ashley Signature Design P016-772. Ashley Signature Design P016-772 16 pagina's. Outdoor square fire pit
IMPORTANT SAFETY INFORMATION ABOUT
A self-contained LP-gas cylinder for use with this appliance must have a capacity of 20
lbs. and must be equipped with a Type 1 connector and an OP D (overfill protection
device). See Figure 1.
The LP-gas supply cylinder to be used must be constructed and marked in accordance
with the specification for LP- gas cylinders of the U.S. Department of Transportation
(DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinder, Sphere and
Tubes for the Transportation of Dangerous Goods.
The cylinder supply system must be arranged for vapor withdrawal.
The cylinder used must include a collar to protect the cylinder valve.
This appliance shall be used only outdoors in a well-ventilated space and shall
not be used in a building, garage or any other enclosed space.
When this appliance is not is use, the gas must be turned off at the supply
cylinder.
Storage of this appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-ventilated area out of the reach
of children. Disconnected cylinders must have threaded valve plugs tightly installed
and must not be stored in a building, garage or any other enclosed areas.
CSA (Canadian Standards Association) certified to ANSI Z21.97•CSA 2.41-2016
"Outdoor Decorative Gas Appliances".
INPUT
Propane Regulator
Pressure
Natural Gas Minimum
Inlet Pressure
Clearances to
combustible surfaces
P016-772
PROPANE (LP) GAS
Figure 1
SPECIFICATIONS
50,000 Btu/hr
11 inches water column
7 inches water column
Sides: 48in./121.9cm
Top: 72 in. / 182.9 cm
Page 7 of 46