7.0
FIXING THE APPLIANCE (continued)
If the appliance is to be mounted on the inner leaf of a conventional cavity brick wall, or a solid wall,
then the wall plugs and fixing screws provided
may be used. Depending on the condition of the
wall it may be necessary to use additional fixings.
In this situation, any additional fixings and
wallplugs should be of the same size and type as
the ones provided. At the appropriate stage of the
installation, drill four holes using only a 8.0mm
masonry bit to a depth of 43mm. Insert the
wallplugs provided ensuring they are flush to the
wall.
If the appliance is to be mounted on a dry lined
wall or a timber framed construction wall then
efforts should be made to fix in at least two posi-
tions vertically, into one of the wooden studs, or
supporting wooden members of the wall using two
of the fixing screws provided. If this is not achiev-
able then the wall should be strengthened using
appropriate building materials.
If there is no alternative than to rely on some plasterboard fixings then
special cavity screw fixings or hollow wall anchors will be required which are
not supplied with this product. These should be constructed from metal and
not plastic and of the design indicated in figure 4. For further guidance for
wall fixing in timber framed buildings, refer to the current
edition of IGE/UP/7.
750 models: Mark the positions shown as "Fixing points model
L23" on the wall.
600 models: Mark the positions shown as "Fixing points model
P23" on the wall.
If a concealed gas connection is to be made ensure the gas
Plasterboard alone is not con-
sidered to be a structural
material.
It is not recommended to rely
on plasterboard fixings alone
to support the weight of the
appliance.
the chosen type of wall fixings. Insert the wall fixing screws
into the top wall plugs, taking care to leave the screws pro-
truding approximately 5mm from the wall. Now hang the
appliance onto these screws through the two keyhole shaped
holes in the upper brackets on the back panel of the appli-
ance.
Insert the lower fixing screws into the lower wall plugs
through the corresponding fixing holes in the lower part of the back panel. Do not tighten fully.
Before tightening the wall mounting screws fully, at this stage it is recommended to check the hori-
zontal alignment of the appliance with a spirit level, as small adjustments can still be made if neces-
sary. When this has been checked, tighten all four fixing screws fully. To access the upper fixing screws
insert a screwdriver through the round access holes in the front face of the outlet grille (figure 5).
These access holes are located in the same position on all models. If required the outlet grille can be
removed (figure 6).
7.1

CHECKING THE BURNER

There are no imitation fuel bed components to install. The appliance features a ribbon burner which is
designed to produce a continuous band of flame over its length.
The burner should be visually inspected to ensure it is free from any foreign matter.
If it is necessary to clean or dust off the burner then the glass door should be removed by removal of
the four retaining screws. Re-fit the glass door after cleaning or inspection, ensuring the correct orien-
tation and a good seal.
WARNING
Figure 3
supply pipe is in it's
final position and can
enter the appliance in
the
correct
position
when the appliance is
hung on the wall. Drill
the wall as appropriate
for the type of wall as
previously described in
this section, and insert
5
Figure 4
Figure 5
Figure 6
©
2012 Acquisitions of London