Cypress OSM-2400 Snelstarthandleiding - Pagina 2

Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Cypress OSM-2400. Cypress OSM-2400 2 pagina's. Osdp-wiegand converter
Ook voor Cypress OSM-2400: Snelstarthandleiding (2 pagina's)

Cypress OSM-2400 Snelstarthandleiding
Wiegand
Access
Control Panel
Ground
Data 0
Data 1
LED Out
Beeper Out
It is recommended to install the OSM-2400 near the Wiegand
Access Controller to maximize the OSDP run between the
OSM-2400 and the OSDP Reader, which can be encrypted.
DC Power
Wiegand
Supply
Reader
It is recommended to install the OSM-2400 near the Wiegand
Reader to maximize the OSDP run between the OSM-2400
and OSDP Access Controller, which can be encrypted.
ACU Mode Wiring Diagram
DC Power
Supply
Power
Ground
PD Mode Wiring Diagram
Power
Ground
8 - 16 VDC Input
RS-485 B+
Ground
RS-485 A-
Data 0 Output
Ground
Strike N.O.
Data 1 Output
Strike COM
Buzzer Input
Strike N.C.
Ground
Red LED Input
Ground
Green LED Input
8 - 16 VDC Input
OSM-2400
8 - 16 VDC Input
RS-485 B+
Ground
RS-485 A-
Red LED Output
Strike N.O.
Green LED Output
Strike COM
Buzzer Output
Strike N.C.
Ground
Data 0 Input
Data 1 Input
8 - 16 VDC Input
OSM-2400
Ground
Ground
OSDP
Reader
OSDP Access
Control Panel
RS485 A
RS485 B