8. TROUBLESHOOTING TIPS

8.1 No Sound
Check the AC power. Is the power switch on and
illuminated? Check the level meters. If they are operat-
ing, the problem between the mixer and the later compo-
nents in the system. If not, check to see you really have
an input signal and that it is on the desired channel. Check
that you have the master gain controls at the desired op-
erating level.
8.2 Distorted Sound
Something is being overdriven in the signal path.
If the clip indicators are active, reduce the channel lev-
els. If the level meters are constantly in the red, reduce
the Master gain and increase the gain of components fol-
lowing the mixer. There are many gain adjustments in
the mixer itself and probably several others in other sys-
tem components which makes it possible to overdrive an
input section and then incorrectly try to reduce the gain
of the output section. The best way to approach setting
gains is to establish the operating level of input stages
first by setting their gain as high as possible but leaving

9. DIMENSIONS

6.00
0.10
1.15
8
Figure 9.1: Dimensional Drawing for LX-308 Mic/Line Mixer
about 20dB of headroom for loud peaks, then move on to
set the master gain to produce a good meter reading. Pro-
ceed to set the gain of equalizers, limiters, crossovers,
and amplifiers following the mixer in the same manner,
always working toward the later stages of the system.
8.3 Excessive Noise
If the noise is in the form of hiss, the problem is
usually due to an input stage set up for low gain and then
compensating by increasing the master gain. Turn up the
channel level controls and reduce the master gain.
8.4 Excessive hum
This is usually caused by "ground loops" in the
system wiring. A complex sound system with many
sources separated by significant distance and using sev-
eral power outlets has many opportunities for this prob-
lem to occur. If possible, feed everything in the system
from one power source with a common ground.
If you need help, get in touch with your Ashly
dealer or call an Ashly technical service representative at
1-800-828-6308 ext. 125.