Ashly FR-16 Productspecificatie - Pagina 2
Blader online of download pdf Productspecificatie voor {categorie_naam} Ashly FR-16. Ashly FR-16 2 pagina's. Fr remotes network remote controls
Ook voor Ashly FR-16: Bedieningshandleiding (17 pagina's), Bedieningshandleiding (12 pagina's)
FR
REMOTES
A
& e
rChiteCt
NgiNeeriNg
FR-8
The remote level control shall be Ethernet based and powered using Class 2 IEEE 802.3af Power over Ethernet (PoE). It shall have automatic IP addressing. It shall have eight (8) faders that can
be assigned in software as input or output level controls, as well as output mixer source level controls. Each fader shall have assignable fader scaling. Each fader shall include a push-button LED,
which is configurable to display mute or signal level status. Push-button LED signal level indicators shall have assignable turn-on thresholds for green and amber. The remote level control shall
have a communication failure indicator. The remote level control shall have one master fader for overall level control of all selected faders. All faders and push-button LEDs shall have a clear win-
dow for insertion of user labels. The remote level control shall have a rear panel lock-out contact closure to disable all controls. The remote level control shall be designed to mount in a standard
four ganged US electrical wall box, to a flat surface with a cutout, or freestanding on a desktop.
The remote level control shall be the Ashly FR-8
FR-16
The remote level control shall be Ethernet based and powered using Class 2 IEEE 802.3af Power over Ethernet (PoE). It shall have automatic IP addressing. It shall have sixteen (16) faders that can
be assigned in software as input or output level controls, as well as output mixer source level controls. Each fader shall have assignable fader scaling. Each fader shall include a push-button LED,
which is configurable to display mute or signal level status. Push-button LED signal level indicators shall have assignable turn-on thresholds for green and amber. The remote level control shall
have a communication failure indicator. The remote level control shall have one master fader for overall level control of all selected faders. All faders and push-button LEDs shall have a clear win-
dow for insertion of user labels. The remote level control shall have a rear panel lock-out contact closure to disable all controls. The remote level control shall be designed to mount in a standard
modular seven ganged US electrical wall box, to a flat surface with a cutout, or freestanding on a desktop.
The remote level control shall be the Ashly FR-16