Cypress Envirosystems WGR Gebruikershandleiding - Pagina 12
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Cypress Envirosystems WGR. Cypress Envirosystems WGR 14 pagina's. Wireless gauge reader
1. Press "►" to access the WGR menu.
2. Press "►" until the bottom right side of the display reads DATA.
3. Press "●" to select this option.
4. Press "►" to scroll through different data parameters until you reach VER.
5. The firmware version of the WGR will show on the display.
6. Press "◄" to exit the menu and return to the normal operating display screen, or if no button is
pressed for 10 seconds, the WGR will automatically return to the normal operating display screen.
5.6
Configuration and Setup Menus
The CONFG and SETUP menus are primarily restricted and for use by qualified service technicians to
configure and install the WGR. With the exception of turning off the WGR, both menus are access
restricted.
6.0 Care and Maintenance
6.1
Calibration
Calibration is performed when WGR is configured during installation. Calibration is performed based on
the position of the WGR with respect to the gauge face.
Re-calibration not required if the WGR is not removed from gauge or the position of the WGR with
respect to the gauge face is not shifted.
If the WGR is removed from gauge face, contact a service technician to re-calibrate the WGR. Simply
repositioning the WGR on the gauge may result in erroneous readings. See Section 10.0, Support, for
contact information.
6.2
Battery Life
Each WGR comes with two lithium batteries. Battery status can be monitored on the LCD of the WGR, or
through the user interface connected to the Blue Box Server. Battery change-out must be performed by a
qualified service technician. See Section 10.0, Support, for contact information.
The battery life of the WGR is dependent on the sampling frequency. Typical ranges are listed below.
7.0 Troubleshooting
The WGR will not turn on.
Please contact a qualified service technician. See Section 10.0, Support, for contact information.
The WGR display shows ERROR in the upper left corner.
The ERROR message appears on the LCD when the WGR is having a problem obtaining a reading from the
gauge. Common causes for this are:
i)
The WGR has been moved from its configured position.
Cypress Envirosystems
Doc # 152-10101-01 Rev 1.2
Sampling Frequency
1 sample per 5 minutes
1 sample per 15 minutes
1 sample per hour
1 sample per day
WGR User Manual
Estimated Battery Life
1 year
2 years
3 years
3.5 years