ASI 0391-1A Installatie- en onderhoudshandleiding - Pagina 8
Blader online of download pdf Installatie- en onderhoudshandleiding voor {categorie_naam} ASI 0391-1A. ASI 0391-1A 16 pagina's. Soap dispenser and remote control
INSTALLATION
Remove the protective sticker
5
covering the sensor. Keep away
from the sensor range.
Connect the Com Cable motor connector to the mating plug
from dispenser (If not already connected in Step 3 above).
6
Please note that since the connector is water proof, some
friction will apply.
O-RING VISIBLE –
IMPROPERLY CONNECTED
Important: the 4 contacts connector should be inserted fully so
that the white O-ring is not visible and a clicking sound is heard.
NOTICE: If the 4 contacts connectors are not connected properly,
the motor will run continuously.
7
1408201627 Rev G
CONNECTING THE POWER SOURCE
ONLY THE GROOVES ARE VISIBLE -
CONNECTED PROPERLY
05 August 2015