Egcon MP3 Gebruikershandleiding - Pagina 5
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Egcon MP3. Egcon MP3 9 pagina's. Acu (ats control unit)
ACU-MP3 Manual
5. Setting DIP SWITCH
Function
COM. VOLT
SELECT
COM TRANSFER
TIME DELAY
GEN TRANSFER
TIME DELAY
VOLT ERROR
RANGE
5.1. COM VOLT SELECT : Selecting commercial input voltage, inter-phase voltage(L-N)
5.2. COM TRANSFER TIME DELAY : Transfer time delay to commercial power when commercial
power is normal during the AUTO mode.
5.3. GEN. TRANSFER TIME DELAY : Transfer time delay to generator power when generator
power is normal during the AUTO mode.
5.4. VOLT ERROR RANGE : Range of Normal Commercial Power Voltage(If 195~245Vac is
input during 220V input and setting for 10%)
SWITCH No.
1
2
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
3
4
5
ON
OFF
ON
OFF
EGCON CO., LTD
Setting
220 Vac (L-N)
230 Vac (L-N)
10 Sec
30 Sec
1 Min
3 Min
2 Sec
5 Sec
10%
15%