Note: When the D12 is operated in "Mix TOP/SUB mode",
the SenseDrive function is only available at the output B
connector.
In permanent installations, SenseDrive can also be applied to
cabinets with NL4 connectors or the fixed cable option (PG). The
connection of the negative signal wire (EP5 pin 4 of the respective
D12 output) to the SenseDrive wire (EP5 pin 5 of respective D12
output) is made in a breakout box close to the loudspeaker
cabinet. For an uncompromising SenseDrive performance the
connection should be done not more than 3 m (10 ft) away from
the loudspeaker.

2.3 Operation

NOTICE!
Only operate d&b loudspeakers with a correctly configured d&b
amplifier, otherwise there is a risk of damaging the loudspeaker
components.
Applicable d&b amplifiers:
D80/D20/D12/D6/10D/30D.
Application
Setup
Yi-SUB
Y-SUB
Within applicable amplifiers, the controller setup is available in
Dual Channel or Mix TOP/SUB mode.

2.3.1 Controller settings

For acoustic adjustment the 100 Hz mode can be selected.
100 Hz mode
With the 100 Hz mode selected, the upper operating frequency of
the system is reduced from 140 Hz to 110 Hz.
Cabinets per
channel
2