BUZZER SRL400 TECHNICAL SPECIFICATIONS
Power supply
Maximum current
minimum operating voltage (positive missing)
essential frequency
secondary frequency
sound pressure
max sound duration
IP category
operating temperature
Buffer battery
Antiapertura / Anti-opening / Autoprotection
Cover / Housing / Boiter
weight
Dimensioni / Dimensions
TRANSMISSION MODULE - TECHNICAL SPECIFICATIONS
Power supply
Maximum current
minimum operating voltage (positive missing)
MAX open-collector current
Radio frequency
operating temperature
The installation must be carried out to state of the art by specialized personnel.
AMC Elettronica S.r.l. rejects any responsibility in the case that the product is tampered with by unauthorized persons.
We recommend that you check that the alarm system is working properly at least once a month. A reliable electronic alarm system does not
prevent break-in, theft, fire or other, but only lowers the risk of the latter occurring.
www.amcelettronica.com
13.8Vcc nominal
1.3A
6Vcc
1,400Hz/1,700Hz
1600Hz/3500Hz
110dB@1mt
15'
IP54
between -25℃ to +55℃
12V 2.2Ah
steel/ABS
13.8Vcc nominal
40mA
6Vcc
50mA
433.27Mhz - 433.92Mhz - 434.57Mhz @ 10mW
between -25℃ to +55℃
6