10. Technical parameters
PARAMETER
sensor type
measured values
types of estimates
power supply
power consumption
low-pass filter
high-pass filter
insulation
current output:
voltage output
delay
alarm level
warning level
relay outputs
operating temperature
operating relative humidity
protection class
dimensions
mounting
14
VALUE
IEPE, 100mV/g , 8mA/20V
velocity, acceleration
RMS, 0-PEAK
24 VDC (18..36 VDC)
<4 W
1 and 10 kHz, 24 dB/oct., 4
3 and 10 Hz, 12 dB/oct., 2
1kV DC (2 or 3 kV DC optionally)
2 or 3 wired 4..20 mA current loop
AC, 10V
max
pp
0 - 16s every 1s
0 – 99
0 – 99
24V/100mA, NO
o
-20..+60
C
<95% RH
IP40
23 x 100 x 120 (W x H x L)
35 mm DIN rail
th
order
nd
order
AV MONITOR 1002D