FLO-DYNAMICS VacFill3 Podręcznik - Strona 13
Przeglądaj online lub pobierz pdf Podręcznik dla Sprzęt serwisowy FLO-DYNAMICS VacFill3. FLO-DYNAMICS VacFill3 20 stron.
OPERATING PROCEDURES for VacFill
IMPORTANT: Machine needs at least 115psi of air to operate.
SUCTION WAND PROCEDURE:
1. Connect Wand Adapter to service line & open Ball Valve.
2. Turn Overflow Valve on back of machine to "Normal Service Position".
3. Turn Right Dial to "Vacuum/Drain Waste" position.
4. Turn Left Dial to "Air On" position to start.
5. Turn Left Dial to "Air Off" position when finished.
REMOVE & FILL PROCEDURE:
1. Make sure vehicle is turned off, but at operating temperature.
2. Turn Overflow Valve on back of machine to "Normal Service Position".
3. Connect Wand Adapter to service hose, open Ball Valve, turn Left Dial to "Air On"
position and Right Dial to "Vacuum/Drain Waste" position to remove waste fluid from
overflow bottle.
4. When overflow bottle is empty, turn Left Dial to "Air Off" position.
5. Remove radiator cap.
6. Connect Cone Adapter to service line.
7. Turn Right Dial to "Vacuum/Drain Waste" position.
8. Turn Left Dial to "Air On" position.
9. Open Ball Valve on service hose.
10. Insert Cone Adapter into radiator, making sure the tip of the cone is submerged.
HINT: If servicing from bottle, insert a hose into the cone long enough to reach
near the bottom of the bottle (hose not supplied).