FLO-DYNAMICS CMS-120 Skrócona instrukcja obsługi

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Urządzenia przemysłowe FLO-DYNAMICS CMS-120. FLO-DYNAMICS CMS-120 8 stron. Coolant management system

40201194
CMS-120
QUICK START
Coolant Management System
INSTRUCTIONS
OPERATION
SAFETY RECOMMENDATIONS
Use extreme safety measures when working around a running engine, pressurized storage vessels, and automotive chemicals.
Always block the vehicle's drive wheels.
Ventilate the vehicle's exhaust if engine will be started.
Always wear safety glasses.
Protective gloves are recommended.
PREPARATION
Inspect the engine and the visible coolant system
components for any signs of damage or unusual wear.
Note the coolant level before beginning the service. If low,
see "COOLING SYSTEM PRESSURE / LEAK CHECK"
procedure to verify the system's condition.
Depending on the desired service, make appropriate
connections (lowest and highest point) on the vehicle's
coolant system.
Plug any open ports venting to the atmosphere (i.e.
overflow hose or a system vent cap).
To prevent running out of coolant and ingesting air, ensure
coolant tank level is showing at least 3 gallons on the sight
tube.
PERFORM COOLANT DRAIN and CLEAN OPERATION
DRAIN COOLANT FROM VEHICLE INTO COOLANT
TANK
Obtain a coolant sample if needed.
Move the Flow Control to "OFF" and connect shop air.
Connect the red service hose to highest point, the black
service hose to the lowest point, and open the ball valves.
Turn all control panel valves to the YELLOW position.
Move the Flow Control to "ON".
The system will begin to drain.
Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874
Page 1 of 8