6 System Troubleshooting and Maintenance
For troubleshooting issues related to 6000E, see the 6000E Operator's Manual
Check in order as listed
System is not powering on
• Check if system is plugged in.
• Check if power cord wires are loose or unsecured in the terminals.
• Check if power outlet or lead is functioning correctly.
System is not activating solenoids
• Check connections from PLC and to the terminals. See wiring diagrams for
correct connections if necessary.
• Check connections to solenoid caps.
• If the lights inside the caps are functioning, check the connection
between the cap and solenoid on the 6000E.
Low level indicator is not functioning
• Check connections to the light and inputs on the ETC.
• Check wiring at the low-level switch on the reservoir.
LCD screen not displaying correct window
This error can occur from pressing the OK and ESC buttons at the same time
• Press any button on the PLC inside the ETC.
• Turn the ETC off and on.
Recommended Spares
6000-ETC Operator's Manual
Description
Lighted cap for solenoid 24VDC
Cable gland
Part Number
E-01013-61
110VAC
E-01013-11
69915K54
Quantity
2
1