3 Assembly and Installation

PRIOR TO GETTING STARTED

WARNING! The AMCOL 6000P series applicator is serviced by a high-pressure air source.
Pressurized air is inherently dangerous and only qualified individuals should be allowed to
work on these systems.
WARNING! Wear safety glasses at all times.
WARNING! Lock out service air during assembly, disassembly, and related repairs.
WARNING! Tighten all hose and fittings prior to operation.
WARNING! Only use fluids that are compatible with aluminum, brass, steel, urethane,
nylon, and acrylic.

Installation

1. Review your applicator to see that no damage has occurred in shipment.
2. See that all your components and the related mounting are appropriate for your
piece of equipment.
3. Ensure that your plant air source has the required capacity and is available, clean,
and dry.
4. Mount the system controls in a protected area, which can be easily accessed by
operations and maintenance personnel. Some components may require minor
assembly as they have been shipped independently to avoid damage in transit.
5. Attach liquid reservoir to the system controls.
6. Mount transition blocks/manifold to the machine, while carefully observing that
these items will not interfere with the activities associated with the use, maintenance,
and adjustment of your machine.
7. Spray tips should be mounted at the maximum distance from and directly at the
spray target. This may require additional adjustments once the system is fully
operational.
8. Connect system actuation to your machine controls.
9. Connect plant air source and set the filter-regulator to 60 psi.
10. Fill the liquid reservoir and then open the shut-off valve on the bottom of the
reservoir.
11. Manually actuate system, observing that system is leak free and all adjustments are
operational. The manual actuator is a push button over-ride recessed toward the
top of the solenoid.
12. Under careful observation, operate system in production environment.
6000P PNEUMATICALLY CONTROLLED PRECISION LUBRICATION SYSTEM
Operator's Manual
P A G E | 4