Amcor plda 19EH Instrukcja obsługi - Strona 13

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Osuszacz powietrza Amcor plda 19EH. Amcor plda 19EH 16 stron. Home air treatment centre

Amcor plda 19EH Instrukcja obsługi
CONTINUOUS DRAINAGE (OPTIONAL)
For the continuous drainage please refer to the
following instructions and pictures :
1. Cut out the hole for the drainage tube on
the back of the unit.
There are 4 tiny strips holding the cover in
the hole, just cut them and the cover will
come out.
2. Push the supplied drain tube through the
hole in the back of the unit and fix it on to
the plastic drain tube.
3. The water tank have to remain in place also
in the continuous drainage.
4. Make sure that the drain tube will have a
continuous downward slop all the way to the
drain point.
5. Do not insert the edge of the drain tube below the water level.
SPOT DEHUMIDIFICATION
Normal dehumidification
Before you start the unit, open the air outlet grill
located behind the control panel to direct the
dehumidified dry air run up according to your
wish.
Spot dehumidification
Your dehumidifier has got a unique feature.
Besides dehumidifying the air in the room it can
at the same time dehumidify humid spots like
closets, shoes, dresses etc. by a flexible hose
connected to the rear panel:
• take off the cover of the scent emitter
• take out the scent capsule
• screw the flexible hose into its adapter
• connect the adapter to the opening in the rear
panel
• close the air outlet panel on the top of the unit
• run the unit.
GB
13