Oakdale FB1 A5 0414-1 30/04/2014 16:27 Page 3
Nominal heat output
Chimney draft required
Height
Width
Depth
Weight
Air Requirement
Flue Mass Gas Flow
2
CO @ 13% O
Mean Flue Gas Temperature
Efficiency
Log Length
*** Please note that Building Regulations Document J advises that additional permanent air supply is
required for appliances with an output of above 5Kw.
With modern properties additional air may be required as Document J suggests that adequate air
would be a benefit.
• If design air permeability ≥5.0m³/ (h.m²) then 550mm²/kW of appliance rated output above 5kW
Or
• If design air permeability ≤5.0m³/ (h.m²) then 550mm²/kW of appliance rated output
• If in doubt, please consult your registered installer for advice.
NOTE: DO NOT INSTALL IN A ROOM CONTAINING AN EXTRACTOR FAN
Oakdale Specifications
5 kW - Wood
12Pa
550 mm
440 mm
370 mm
90 kg
N/A ***
3.4g/s - Wood
0.08 vol %
274°C - Wood
78.3% - Wood
Up To 300 mm
440
5 kW – Smokeless Fuel
4.7g/s - Smokeless Fuel
273°C - Smokeless Fuel
81.5% - Smokeless Fuel
370